• page_banner

Product

China wholesale Cgl Vacuum Interrupter Factory – Vacuum interrupter for MV VCB, VS1 ZN28 ZN63 – Shone


Product Detail

Product Tags

Related Video

Feedback (2)

Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs for Vacuum Circuit Breaker Uses, Application Of Sf6 Circuit Breaker, 11kv Load Break Switch, Standing still today and searching into the long run, we sincerely welcome shoppers all around the globe to cooperate with us.
China wholesale Cgl Vacuum Interrupter Factory – Vacuum interrupter for MV VCB, VS1 ZN28 ZN63 – Shone Detail:

Brief description of the product:

When the fault occurs in the system, the contacts of the breaker are moved apart and hence the arc is developed between them. When the current carrying contacts are pulled apart, the temperature of their connecting parts is very high due to which ionization occurs. Due to the ionization, the contact space is filled with vapour of positive ions which is discharged from the contact material.
The density of vapour depends on the current in the arcing. Due to the decreasing mode of current wave their rate of release of vapour fall and after the current zero, the medium regains its dielectric strength provided vapour density around the contacts reduced. Hence, the arc does not restrike again because the metal vapour is quickly removed from the contact zone.

ngg3
vf21

Pay attention

Strictly control the closing and opening speed of vacuum circuit breaker.
For the vacuum circuit breaker with a certain structure, the manufacturer has specified the best closing speed. When the closing speed of vacuum circuit breaker is too low, the wear of contact will increase due to the extension of pre breakdown time; When the vacuum circuit breaker is disconnected, the arcing time is short, and its maximum arcing time does not exceed 1.5 power frequency half wave. It is required that when the current crosses zero for the first time, the arc extinguishing chamber should have sufficient insulation strength. Generally, it is expected that the stroke of the contact in the power frequency half wave will reach 50% – 80% of the full stroke during circuit breaking. Therefore, the opening speed of the circuit breaker should be strictly controlled. As the arc extinguishing chamber of vacuum circuit breaker generally adopts brazing process, its mechanical strength is not high, and its vibration resistance is poor. Too high closing speed of circuit breaker will cause greater vibration, and will also have greater impact on bellows, reducing the service life of bellows. Therefore, the closing speed of vacuum circuit breaker is usually set as 0.6 ~ 2m / s.


Product detail pictures:

China wholesale Cgl Vacuum Interrupter Factory –  Vacuum interrupter for MV VCB, VS1 ZN28 ZN63  – Shone detail pictures


Related Product Guide:

We usually believe that one's character decides products' high quality, the details decides products' excellent ,with the REALISTIC,EFFICIENT AND INNOVATIVE staff spirit for China wholesale Cgl Vacuum Interrupter Factory – Vacuum interrupter for MV VCB, VS1 ZN28 ZN63 – Shone , The product will supply to all over the world, such as: Marseille, Hungary, Hongkong, We accomplish this by exporting our wigs directly from our own factory to you. The goal of our company is to get customers who enjoy coming back to their business. We sincerely hope to cooperate with you in the near future. If there's any opportunity, welcome to visit our factory!!!
  • This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By ROGER Rivkin from Jakarta - 2018.09.29 13:24
    The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Lisa from Sri Lanka - 2017.01.28 18:53
    Write your message here and send it to us