Sticking towards the principle of "Super High-quality, Satisfactory service" ,We've been striving to become a superb business partner of you for 11 Kv Outdoor Vacuum Circuit Breaker, Switch Gear Panel, Vcb Breaker Parts, Our group members are goal to provides merchandise with significant performance cost ratio to our consumers, as well as target for all of us is usually to satisfy our consumers from all around the environment.
China wholesale Medium-Voltage Vacuum Interrupter For VCB Factory – Vacuum interrupter for MV VCB(ceramic shell, Rated voltage: 7.2kV-12kV) – Shone Detail:

Brief description of the product:

Current chopping in vacuum circuit breaker depends on the vapour pressure and the electron emission properties of the contact material. The chopping level is also influenced by the thermal conductivity–lower the thermal conductivity, lower is the chopping level.
It is possible to reduce the current level at which chopping occurs by selecting a contact material which gives out sufficient metal vapour to allow the current to come to a very low value or zero value, but this is rarely done as it affects the dielectric strength adversely.
High insulating strength: In comparison to various other insulating media used in circuit breaker vacuum is a superior dielectric medium. It is better than all other media except air and SF6, which are employed at high pressure.
When an arc is opened by moving apart the contacts in a vacuum, an interruption occurs at the first current zero. With the arc interruption, their dielectric strength increases up to a rate of thousands time as compared to other breakers.

feq
ssqdw

Pay attention

(1) Measures to prevent overvoltage. Vacuum circuit breaker has good breaking performance. Sometimes when breaking inductive load, high overvoltage is generated at both ends of inductance due to rapid change of loop current. Therefore, for dry-type transformers and other equipment with low impulse voltage resistance, it is best to install overvoltage protection devices, such as metal oxide arresters.
(2) Strictly control the load current.
The overload capacity of vacuum circuit breaker is poor. Since thermal insulation is formed between the contact and the shell of the vacuum circuit breaker, the heat on the contact and the conductive rod is mainly transmitted along the conductive rod. In order to make the operating temperature of the vacuum circuit breaker not exceed the allowable value, its working current must be strictly limited to be lower than the rated current.


Product detail pictures:

China wholesale Medium-Voltage Vacuum Interrupter For VCB Factory –  Vacuum interrupter for MV VCB(ceramic shell, Rated voltage: 7.2kV-12kV) – Shone detail pictures


Related Product Guide:

Sticking towards the principle of "Super High-quality, Satisfactory service" ,We've been striving to become a superb business partner of you for China wholesale Medium-Voltage Vacuum Interrupter For VCB Factory – Vacuum interrupter for MV VCB(ceramic shell, Rated voltage: 7.2kV-12kV) – Shone , The product will supply to all over the world, such as: Barbados, Norwegian, Ghana, We warmly welcome you to come to visit us personally. We hope to establish a long-term friendship based on equality and mutual benefit. If you want to get in touch with us, please do not hesitate to call. We will be your best choice.
  • The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Eden from Romania - 2018.07.27 12:26
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Edwina from Bangalore - 2018.12.10 19:03
    Write your message here and send it to us