With this motto in mind, we've got become among essentially the most technologically innovative, cost-efficient, and price-competitive manufacturers for Different Types Of Breakers, Outdoor Vacuum Switch, Breaking Current Of Circuit Breaker, Accurate process devices, Advanced Injection Molding Equipment, Equipment assembly line, labs and software advancement are our distinguishing feature.
China wholesale Vacuum Interrupter Working Supplier – Vacuum interrupter for MV VCB, VS1 ZN28 ZN63 – Shone Detail:

Brief description of the product:

When the fault occurs in the system, the contacts of the breaker are moved apart and hence the arc is developed between them. When the current carrying contacts are pulled apart, the temperature of their connecting parts is very high due to which ionization occurs. Due to the ionization, the contact space is filled with vapour of positive ions which is discharged from the contact material.
The density of vapour depends on the current in the arcing. Due to the decreasing mode of current wave their rate of release of vapour fall and after the current zero, the medium regains its dielectric strength provided vapour density around the contacts reduced. Hence, the arc does not restrike again because the metal vapour is quickly removed from the contact zone.

ngg3
vf21

Pay attention

Strictly control the closing and opening speed of vacuum circuit breaker.
For the vacuum circuit breaker with a certain structure, the manufacturer has specified the best closing speed. When the closing speed of vacuum circuit breaker is too low, the wear of contact will increase due to the extension of pre breakdown time; When the vacuum circuit breaker is disconnected, the arcing time is short, and its maximum arcing time does not exceed 1.5 power frequency half wave. It is required that when the current crosses zero for the first time, the arc extinguishing chamber should have sufficient insulation strength. Generally, it is expected that the stroke of the contact in the power frequency half wave will reach 50% – 80% of the full stroke during circuit breaking. Therefore, the opening speed of the circuit breaker should be strictly controlled. As the arc extinguishing chamber of vacuum circuit breaker generally adopts brazing process, its mechanical strength is not high, and its vibration resistance is poor. Too high closing speed of circuit breaker will cause greater vibration, and will also have greater impact on bellows, reducing the service life of bellows. Therefore, the closing speed of vacuum circuit breaker is usually set as 0.6 ~ 2m / s.


Product detail pictures:


Related Product Guide:

Together with the "Client-Oriented" enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for China wholesale Vacuum Interrupter Working Supplier – Vacuum interrupter for MV VCB, VS1 ZN28 ZN63 – Shone , The product will supply to all over the world, such as: Vancouver, Seychelles, Russia, If you give us a list of merchandise you are interested in, along with makes and models, we can send you quotations. Remember to email us directly. Our goal is to establish long-term and mutually profitable business relationships with domestic and overseas clients. We look forward to receiving your reply soon.
We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
5 Stars By Lindsay from Honduras - 2017.10.23 10:29
Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
5 Stars By Pearl from Slovenia - 2018.06.09 12:42
Write your message here and send it to us